NCCOOS Trac Projects: Top | Web | Platforms | Processing | Viz | Sprints | Sandbox | (Wind)

root/spongenet/trunk/spongenet/tests/expand/xmlref/2010_05/20100501T004758-20100501T011228/20100501T005028.xml

Revision 337 (checked in by cbc, 14 years ago)

Initial import.

Line 
1 <?xml version="1.0" encoding="utf-8"?>
2 <Device ID="4887-231" SessionID="4887-231-2010-04-28T15:39:14Z" Descr="Platform" SerialNo="231" ProdNo="4887" ProdName="Seaguard Datalogger IW" DeviceType="Instrument" ProtocolVer="4" xmlns="http://www.aadi.no/RTOutSchema">
3         <Time>2010-05-01T00:50:26Z</Time>
4         <Status>0:OK</Status>
5         <SiteInfo>
6                 <Location>NURC</Location>
7                 <VerticalPosition>0</VerticalPosition>
8                 <Owner>UNC Chapel Hill</Owner>
9         </SiteInfo>
10         <Data RecordNumber="6831" Time="2010-05-01T00:50:23Z" SessionID="2010-04-28T15:54:56Z">
11                 <SensorData ID="SN100-0" SerialNo="0" ProdNo="SN100" ProdName="System Node" Descr="System Parameters" Adr="-4" ProtocolVer="3" VerticalPosition="0">
12                         <Status>0:OK</Status>
13                         <Parameters>
14                                 <Point ID="0" Descr="Battery Voltage" Type="VT_R4" Format="" Unit="V" RangeMin="0" RangeMax="15">
15                                         <Value>12.1255</Value>
16                                 </Point>
17                                 <Point ID="1" Descr="Memory Used" Type="VT_I4" Format="" Unit="Bytes" RangeMin="0" RangeMax="14024704">
18                                         <Value>11493376</Value>
19                                 </Point>
20                                 <Point ID="2" Descr="Interval" Type="VT_I4" Format="" Unit="ms" RangeMin="" RangeMax="">
21                                         <Value>29994</Value>
22                                 </Point>
23                         </Parameters>
24                 </SensorData>
25                 <SensorData ID="AN100-0" SerialNo="0" ProdNo="AN100" ProdName="Analog Sensors" Descr="Turbidity #11692" Adr="-3" ProtocolVer="3" VerticalPosition="0">
26                         <Status>0:OK</Status>
27                         <Parameters>
28                                 <Point ID="3" Descr="Turbidity" Type="VT_R8" Format="" Unit="FTU" RangeMin="0" RangeMax="125">
29                                         <Value>1.59859</Value>
30                                 </Point>
31                         </Parameters>
32                 </SensorData>
33                 <SensorData ID="4330F-127" SerialNo="127" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#127" Adr="340736" ProtocolVer="1" VerticalPosition="0">
34                         <Status>0:OK</Status>
35                         <Parameters>
36                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
37                                         <Value>252.62</Value>
38                                 </Point>
39                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
40                                         <Value>97.9784</Value>
41                                 </Point>
42                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
43                                         <Value>24.9666</Value>
44                                 </Point>
45                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
46                                         <Value>27.6007</Value>
47                                 </Point>
48                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
49                                         <Value>29.6228</Value>
50                                 </Point>
51                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
52                                         <Value>32.5698</Value>
53                                 </Point>
54                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
55                                         <Value>2.94698</Value>
56                                 </Point>
57                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
58                                         <Value>493.327</Value>
59                                 </Point>
60                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
61                                         <Value>724.945</Value>
62                                 </Point>
63                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
64                                         <Value>-173.994</Value>
65                                 </Point>
66                         </Parameters>
67                 </SensorData>
68                 <SensorData ID="4330F-167" SerialNo="167" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#167 " Adr="352512" ProtocolVer="1" VerticalPosition="0">
69                         <Status>0:OK</Status>
70                         <Parameters>
71                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
72                                         <Value>246.343</Value>
73                                 </Point>
74                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
75                                         <Value>95.5486</Value>
76                                 </Point>
77                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
78                                         <Value>24.9693</Value>
79                                 </Point>
80                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
81                                         <Value>27.8661</Value>
82                                 </Point>
83                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
84                                         <Value>27.503</Value>
85                                 </Point>
86                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
87                                         <Value>32.5124</Value>
88                                 </Point>
89                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
90                                         <Value>5.00935</Value>
91                                 </Point>
92                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
93                                         <Value>500.789</Value>
94                                 </Point>
95                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
96                                         <Value>688.323</Value>
97                                 </Point>
98                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
99                                         <Value>140.234</Value>
100                                 </Point>
101                         </Parameters>
102                 </SensorData>
103                 <SensorData ID="4330F-169" SerialNo="169" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#169" Adr="353024" ProtocolVer="1" VerticalPosition="0">
104                         <Status>0:OK</Status>
105                         <Parameters>
106                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
107                                         <Value>230.006</Value>
108                                 </Point>
109                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
110                                         <Value>89.2198</Value>
111                                 </Point>
112                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
113                                         <Value>24.9739</Value>
114                                 </Point>
115                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
116                                         <Value>28.5965</Value>
117                                 </Point>
118                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
119                                         <Value>28.5071</Value>
120                                 </Point>
121                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
122                                         <Value>33.4343</Value>
123                                 </Point>
124                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
125                                         <Value>4.92722</Value>
126                                 </Point>
127                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
128                                         <Value>558.538</Value>
129                                 </Point>
130                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
131                                         <Value>676.17</Value>
132                                 </Point>
133                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
134                                         <Value>-138.587</Value>
135                                 </Point>
136                         </Parameters>
137                 </SensorData>
138                 <SensorData ID="4330F-170" SerialNo="170" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#170" Adr="353280" ProtocolVer="1" VerticalPosition="0">
139                         <Status>0:OK</Status>
140                         <Parameters>
141                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
142                                         <Value>249.686</Value>
143                                 </Point>
144                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
145                                         <Value>96.8369</Value>
146                                 </Point>
147                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
148                                         <Value>24.9647</Value>
149                                 </Point>
150                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
151                                         <Value>27.725</Value>
152                                 </Point>
153                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
154                                         <Value>28.2648</Value>
155                                 </Point>
156                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
157                                         <Value>32.5183</Value>
158                                 </Point>
159                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
160                                         <Value>4.25349</Value>
161                                 </Point>
162                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
163                                         <Value>499.118</Value>
164                                 </Point>
165                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
166                                         <Value>625.558</Value>
167                                 </Point>
168                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
169                                         <Value>-32.2017</Value>
170                                 </Point>
171                         </Parameters>
172                 </SensorData>
173                 <SensorData ID="4330F-171" SerialNo="171" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#171" Adr="353536" ProtocolVer="1" VerticalPosition="0">
174                         <Status>0:OK</Status>
175                         <Parameters>
176                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
177                                         <Value>218.022</Value>
178                                 </Point>
179                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
180                                         <Value>84.5609</Value>
181                                 </Point>
182                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
183                                         <Value>24.9673</Value>
184                                 </Point>
185                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
186                                         <Value>29.1759</Value>
187                                 </Point>
188                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
189                                         <Value>28.4585</Value>
190                                 </Point>
191                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
192                                         <Value>34.4114</Value>
193                                 </Point>
194                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
195                                         <Value>5.95294</Value>
196                                 </Point>
197                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
198                                         <Value>610.566</Value>
199                                 </Point>
200                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
201                                         <Value>588.877</Value>
202                                 </Point>
203                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
204                                         <Value>18.1129</Value>
205                                 </Point>
206                         </Parameters>
207                 </SensorData>
208                 <SensorData ID="4330F-172" SerialNo="172" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#172" Adr="353792" ProtocolVer="1" VerticalPosition="0">
209                         <Status>0:OK</Status>
210                         <Parameters>
211                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
212                                         <Value>249.66</Value>
213                                 </Point>
214                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
215                                         <Value>96.824</Value>
216                                 </Point>
217                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
218                                         <Value>24.9631</Value>
219                                 </Point>
220                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
221                                         <Value>27.7267</Value>
222                                 </Point>
223                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
224                                         <Value>28.1389</Value>
225                                 </Point>
226                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
227                                         <Value>32.6407</Value>
228                                 </Point>
229                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
230                                         <Value>4.50181</Value>
231                                 </Point>
232                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
233                                         <Value>556.411</Value>
234                                 </Point>
235                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
236                                         <Value>661.003</Value>
237                                 </Point>
238                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
239                                         <Value>-103.431</Value>
240                                 </Point>
241                         </Parameters>
242                 </SensorData>
243                 <SensorData ID="4330F-173" SerialNo="173" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#173" Adr="354048" ProtocolVer="1" VerticalPosition="0">
244                         <Status>0:OK</Status>
245                         <Parameters>
246                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
247                                         <Value>224.449</Value>
248                                 </Point>
249                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
250                                         <Value>87.0554</Value>
251                                 </Point>
252                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
253                                         <Value>24.9685</Value>
254                                 </Point>
255                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
256                                         <Value>28.8616</Value>
257                                 </Point>
258                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
259                                         <Value>28.8054</Value>
260                                 </Point>
261                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
262                                         <Value>34.0215</Value>
263                                 </Point>
264                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
265                                         <Value>5.21613</Value>
266                                 </Point>
267                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
268                                         <Value>576.964</Value>
269                                 </Point>
270                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
271                                         <Value>597.435</Value>
272                                 </Point>
273                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
274                                         <Value>-2.67653</Value>
275                                 </Point>
276                         </Parameters>
277                 </SensorData>
278                 <SensorData ID="4330F-175" SerialNo="175" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#175" Adr="354560" ProtocolVer="1" VerticalPosition="0">
279                         <Status>0:OK</Status>
280                         <Parameters>
281                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
282                                         <Value>249.031</Value>
283                                 </Point>
284                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
285                                         <Value>96.567</Value>
286                                 </Point>
287                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
288                                         <Value>24.9557</Value>
289                                 </Point>
290                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
291                                         <Value>27.7559</Value>
292                                 </Point>
293                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
294                                         <Value>28.4337</Value>
295                                 </Point>
296                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
297                                         <Value>32.7981</Value>
298                                 </Point>
299                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
300                                         <Value>4.3644</Value>
301                                 </Point>
302                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
303                                         <Value>540.953</Value>
304                                 </Point>
305                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
306                                         <Value>627.907</Value>
307                                 </Point>
308                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
309                                         <Value>-178.489</Value>
310                                 </Point>
311                         </Parameters>
312                 </SensorData>
313                 <SensorData ID="4330F-176" SerialNo="176" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#176" Adr="354816" ProtocolVer="1" VerticalPosition="0">
314                         <Status>0:OK</Status>
315                         <Parameters>
316                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
317                                         <Value>220.14</Value>
318                                 </Point>
319                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
320                                         <Value>85.2981</Value>
321                                 </Point>
322                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
323                                         <Value>24.9141</Value>
324                                 </Point>
325                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
326                                         <Value>29.0917</Value>
327                                 </Point>
328                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
329                                         <Value>29.3724</Value>
330                                 </Point>
331                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
332                                         <Value>34.0563</Value>
333                                 </Point>
334                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
335                                         <Value>4.68391</Value>
336                                 </Point>
337                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
338                                         <Value>583.686</Value>
339                                 </Point>
340                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
341                                         <Value>650.109</Value>
342                                 </Point>
343                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
344                                         <Value>31.8892</Value>
345                                 </Point>
346                         </Parameters>
347                 </SensorData>
348                 <SensorData ID="4330F-178" SerialNo="178" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#178" Adr="355328" ProtocolVer="1" VerticalPosition="0">
349                         <Status>0:OK</Status>
350                         <Parameters>
351                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
352                                         <Value>245.934</Value>
353                                 </Point>
354                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
355                                         <Value>95.188</Value>
356                                 </Point>
357                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
358                                         <Value>24.8547</Value>
359                                 </Point>
360                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
361                                         <Value>27.9261</Value>
362                                 </Point>
363                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
364                                         <Value>27.5237</Value>
365                                 </Point>
366                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
367                                         <Value>32.8271</Value>
368                                 </Point>
369                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
370                                         <Value>5.30345</Value>
371                                 </Point>
372                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
373                                         <Value>531.229</Value>
374                                 </Point>
375                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
376                                         <Value>607.932</Value>
377                                 </Point>
378                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
379                                         <Value>-143.45</Value>
380                                 </Point>
381                         </Parameters>
382                 </SensorData>
383                 <SensorData ID="4330F-179" SerialNo="179" ProdNo="4330F" ProdName="Optode Sensor" Descr="Optode Sensor 4330F#179" Adr="355584" ProtocolVer="1" VerticalPosition="0">
384                         <Status>0:OK</Status>
385                         <Parameters>
386                                 <Point ID="0" Descr="O2Concentration" Type="VT_R4" Format="%0.3f" Unit="uM" RangeMin="0" RangeMax="500">
387                                         <Value>225.214</Value>
388                                 </Point>
389                                 <Point ID="1" Descr="AirSaturation" Type="VT_R4" Format="%0.3f" Unit="%" RangeMin="0" RangeMax="150">
390                                         <Value>87.2103</Value>
391                                 </Point>
392                                 <Point ID="2" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="40">
393                                         <Value>24.8806</Value>
394                                 </Point>
395                                 <Point ID="3" Descr="CalPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
396                                         <Value>28.8582</Value>
397                                 </Point>
398                                 <Point ID="4" Descr="TCPhase" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
399                                         <Value>28.8544</Value>
400                                 </Point>
401                                 <Point ID="5" Descr="C1RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
402                                         <Value>33.7184</Value>
403                                 </Point>
404                                 <Point ID="6" Descr="C2RPh" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="0" RangeMax="90">
405                                         <Value>4.864</Value>
406                                 </Point>
407                                 <Point ID="7" Descr="C1Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
408                                         <Value>505.525</Value>
409                                 </Point>
410                                 <Point ID="8" Descr="C2Amp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="0" RangeMax="3300">
411                                         <Value>628.026</Value>
412                                 </Point>
413                                 <Point ID="9" Descr="RawTemp" Type="VT_R4" Format="%0.1f" Unit="mV" RangeMin="-1500" RangeMax="1500">
414                                         <Value>-18.1532</Value>
415                                 </Point>
416                         </Parameters>
417                 </SensorData>
418                 <SensorData ID="4319-217" SerialNo="217" ProdNo="4319" ProdName="Conductivity Sensor" Descr="Conductivity #217" Adr="362752" ProtocolVer="1" VerticalPosition="0">
419                         <Status>0:OK</Status>
420                         <Parameters>
421                                 <Point ID="0" Descr="Conductivity" Type="VT_R4" Format="%0.3f" Unit="mS/cm" RangeMin="0" RangeMax="75">
422                                         <Value>55.2805</Value>
423                                 </Point>
424                                 <Point ID="1" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="Deg.C" RangeMin="-5" RangeMax="35">
425                                         <Value>24.9751</Value>
426                                 </Point>
427                         </Parameters>
428                 </SensorData>
429                 <SensorData ID="4117D-235" SerialNo="235" ProdNo="4117D" ProdName="Pressure Sensor" Descr="Pressure #235" Adr="366848" ProtocolVer="1" VerticalPosition="0">
430                         <Status>0:OK</Status>
431                         <Parameters>
432                                 <Point ID="0" Descr="Pressure" Type="VT_R4" Format="%0.3f" Unit="kPa" RangeMin="0" RangeMax="1000">
433                                         <Value>285.301</Value>
434                                 </Point>
435                                 <Point ID="1" Descr="Temperature" Type="VT_R4" Format="%0.3f" Unit="DegC" RangeMin="-5" RangeMax="35">
436                                         <Value>24.9736</Value>
437                                 </Point>
438                         </Parameters>
439                 </SensorData>
440                 <SensorData ID="4520-275" SerialNo="275" ProdNo="4520" ProdName="Doppler Current Sensor" Descr="DCS #275" Adr="591360" ProtocolVer="1" VerticalPosition="0">
441                         <Status>0:OK</Status>
442                         <Parameters>
443                                 <Point ID="0" Descr="Abs Speed" Type="VT_R4" Format="%0.3f" Unit="cm/s" RangeMin="0" RangeMax="300">
444                                         <Value>4.35118</Value>
445                                 </Point>
446                                 <Point ID="1" Descr="Direction" Type="VT_R4" Format="%0.3f" Unit="Deg.M" RangeMin="0" RangeMax="360">
447                                         <Value>184.128</Value>
448                                 </Point>
449                                 <Point ID="2" Descr="North" Type="VT_R4" Format="%0.3f" Unit="cm/s" RangeMin="-300" RangeMax="300">
450                                         <Value>-4.33989</Value>
451                                 </Point>
452                                 <Point ID="3" Descr="East" Type="VT_R4" Format="%0.3f" Unit="cm/s" RangeMin="-300" RangeMax="300">
453                                         <Value>-0.313235</Value>
454                                 </Point>
455                                 <Point ID="4" Descr="Heading" Type="VT_R4" Format="%0.3f" Unit="Deg.M" RangeMin="0" RangeMax="360">
456                                         <Value>261.703</Value>
457                                 </Point>
458                                 <Point ID="5" Descr="Tilt X" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="-45" RangeMax="45">
459                                         <Value>-1.15546</Value>
460                                 </Point>
461                                 <Point ID="6" Descr="Tilt Y" Type="VT_R4" Format="%0.3f" Unit="Deg" RangeMin="-45" RangeMax="45">
462                                         <Value>-6.48396</Value>
463                                 </Point>
464                                 <Point ID="7" Descr="SP Std" Type="VT_R4" Format="%0.3f" Unit="cm/s" RangeMin="0" RangeMax="20">
465                                         <Value>5.12208</Value>
466                                 </Point>
467                                 <Point ID="8" Descr="Strength" Type="VT_R4" Format="%0.3f" Unit="dB" RangeMin="-80" RangeMax="0">
468                                         <Value>-38.128</Value>
469                                 </Point>
470                                 <Point ID="9" Descr="Ping Count" Type="VT_I2" Format="%d" Unit="" RangeMin="" RangeMax="">
471                                         <Value>150</Value>
472                                 </Point>
473                         </Parameters>
474                 </SensorData>
475         </Data>
476 </Device>
Note: See TracBrowser for help on using the browser.