Repair Acoustic Release s/n 29207
Status: closed (fixed)
Reported by: | haines | Assigned to: | haines |
---|---|---|---|
Priority: | major | Milestone: | Buoy-System-2010 |
Component: | deployment | Version: | |
Severity: | must have | Keywords: | |
Cc: |
While testing acoustic releases (ticket:53) for deployment on bottom frames found s/n 29207 to be corroded such that the shaft arm to rotating even though unit response to command codes.
Sent it to ORE Offshore (RMA 2033) to get fixed.
Change History
10/13/11 14:57:59: Modified by haines
- status changed from new to assigned.
10/13/11 15:09:43: Modified by haines
- component changed from communication to deployment.
01/11/12 11:51:41: Modified by haines
- status changed from assigned to closed.
- resolution set to fixed.
- description changed.