Changeset 422
- Timestamp:
- 12/16/10 09:43:59
- Files:
-
- q2o/sos_unc/trunk/sos_unc/YSI_6Series_6600V2.xml (modified) (45 diffs)
- q2o/sos_unc/trunk/sos_unc/morgan_ysi.xml (modified) (8 diffs)
Legend:
- Unmodified
- Added
- Removed
- Modified
- Copied
- Moved
q2o/sos_unc/trunk/sos_unc/YSI_6Series_6600V2.xml
r421 r422 9 9 <sml:member> 10 10 <sml:System gml:id="YSI_6Series_6600V2"> 11 11 12 12 <!--============================--> 13 13 <!-- Metadata --> 14 14 <!--============================--> 15 <gml:description>The 6600V2 sonde is a water quality monitoring package available with simultaneous measurement of conductivity (salinity), temperature, depth or level, pH/ORP. With models V2-2 and V2-4, two or four additional optical sensor selections measure parameters of dissolved oxygen, turbidity, chlorophyll, and blue-green algae. Additional calculated parameters include total dissolved solids, resistivity, and specific conductance.</gml:description> 15 <gml:description>The 6600V2 sonde is a water quality monitoring package available with simultaneous measurement of conductivity (salinity), 16 temperature, depth or level, pH/ORP. With models V2-2 and V2-4, two or four additional optical sensor selections measure 17 parameters of dissolved oxygen, turbidity, chlorophyll, and blue-green algae. Additional calculated parameters include total 18 dissolved solids, resistivity, and specific conductance.</gml:description> 16 19 <gml:name>YSI_6Series_6600V2</gml:name> 17 20 <sml:keywords> … … 50 53 </sml:IdentifierList> 51 54 </sml:identification> 52 55 53 56 <!--==========================================================--> 54 57 <!--===================System Classifiers=====================--> … … 56 59 <sml:classification> 57 60 <sml:ClassifierList id="classifiers"> 58 61 59 62 <sml:classifier name="intendedApplication"> 60 63 <sml:Term definition="urn:ogc:def:property:OGC:application"> … … 67 70 </sml:Term> 68 71 </sml:classifier> 69 72 70 73 </sml:ClassifierList> 71 74 </sml:classification> … … 76 79 <swe:DataRecord gml:id="physical_specs" 77 80 definition="urn:ogc:def:property:OGC::physicalProperties"> 78 81 79 82 <swe:field name="weightInAir"> 80 83 <swe:Quantity definition="urn:ogc:def:property:OGC::weight"> … … 83 86 </swe:Quantity> 84 87 </swe:field> 85 88 86 89 <swe:field name="diameter"> 87 90 <swe:Quantity definition="urn:ogc:def:property:OGC::diameter"> … … 91 94 </swe:Quantity> 92 95 </swe:field> 93 96 94 97 <swe:field name="length"> 95 98 <!-- without pressure --> … … 99 102 </swe:Quantity> 100 103 </swe:field> 101 104 102 105 <swe:field name="lengthWithPressure"> 103 106 <swe:Quantity definition="urn:ogc:def:dataType:OGC:1.1:length "> … … 106 109 </swe:Quantity> 107 110 </swe:field> 108 111 109 112 <swe:field name="deepPressureRating"> 110 113 <!-- Deep Depth Option --> … … 115 118 </swe:Quantity> 116 119 </swe:field> 117 120 118 121 <swe:field name="opticalPressureRating"> 119 122 <!-- nominal --> … … 124 127 </swe:Quantity> 125 128 </swe:field> 126 129 127 130 </swe:DataRecord> 128 131 </sml:characteristics> 129 132 130 133 <!--==========================================================--> 131 134 <!--============ System Capabilities =============--> … … 154 157 </swe:DataRecord> 155 158 </sml:capabilities> 156 159 157 160 <!--==========================================================--> 158 161 <!--============ System Contacts =============--> 159 162 <!--==========================================================--> 160 163 161 164 <sml:contact> 162 165 <sml:ContactList gml:id="contact"> … … 182 185 </sml:member> 183 186 </sml:ContactList> 184 </sml:contact>185 187 </sml:contact> 188 186 189 <!--==========================================================--> 187 190 <!--============ System Documentation ============--> 188 191 <!--==========================================================--> 189 192 190 193 <sml:documentation> 191 194 <sml:DocumentList gml:id="documentation"> … … 217 220 </sml:DocumentList> 218 221 </sml:documentation> 219 222 220 223 <!--============================--> 221 224 <!-- Platform Coordinate Frame --> … … 233 236 </gml:EngineeringCRS> 234 237 </sml:spatialReferenceFrame> 235 238 236 239 <!--========================--> 237 240 <!-- Sonde Inputs --> 238 241 <!--========================--> 239 242 240 243 <sml:inputs> 241 244 <sml:InputList id="inputs"> 242 245 <sml:input name="conductivity"> 243 <swe:ObservableProperty 244 definition="http://mmisw.org/ont/ioos/parameter/conductivity" 245 > </swe:ObservableProperty> 246 <swe:ObservableProperty definition="http://mmisw.org/ont/ioos/parameter/conductivity"/> 246 247 </sml:input> 247 248 <sml:input name="water_temperature"> 248 <swe:ObservableProperty 249 definition="http://mmisw.org/ont/ioos/parameter/water_temperature" 250 > </swe:ObservableProperty> 249 <swe:ObservableProperty definition="http://mmisw.org/ont/ioos/parameter/water_temperature"/> 251 250 </sml:input> 252 251 <sml:input name="water_pressure"> 253 252 <swe:ObservableProperty 254 definition="http://mmisw.org/ont/ioos/parameter/water_pressure" 255 > </swe:ObservableProperty> 253 definition="http://mmisw.org/ont/ioos/parameter/water_pressure"/> 256 254 </sml:input> 257 255 <sml:input name="dissolved_oxygen"> 258 256 <swe:ObservableProperty 259 definition="http://mmisw.org/ont/ioos/parameter/dissolved_oxygen" 260 > </swe:ObservableProperty> 257 definition="http://mmisw.org/ont/ioos/parameter/dissolved_oxygen"/> 261 258 </sml:input> 262 259 <sml:input name="acidity"> 263 <swe:ObservableProperty definition="http://mmisw.org/ont/ioos/parameter/acidity" 264 > </swe:ObservableProperty> 260 <swe:ObservableProperty definition="http://mmisw.org/ont/ioos/parameter/acidity"/> 265 261 </sml:input> 266 262 <sml:input name="suspended_solids"> 267 263 <swe:ObservableProperty 268 definition="http://mmisw.org/ont/ioos/parameter/suspended_solids" 269 > </swe:ObservableProperty> 264 definition="http://mmisw.org/ont/ioos/parameter/suspended_solids"/> 270 265 </sml:input> 271 266 </sml:InputList> 272 267 </sml:inputs> 273 268 274 269 <!--==============================--> 275 270 <!-- Sonde Outputs --> … … 344 339 </sml:OutputList> 345 340 </sml:outputs> 346 341 347 342 <!--=======================--> 348 343 <!-- Sonde Parameters --> … … 352 347 <sml:parameter name="SondeParameters"> 353 348 <swe:DataRecord> 349 <!-- How does Lat affect depth measurement? Should be input into components that use it --> 354 350 <swe:field name="Latitude"> 355 351 <swe:Quantity definition="urn:ysi:def:property:::Latitude"> … … 358 354 <swe:constraint> 359 355 <swe:AllowedValues> 360 <swe:interval>0 90</swe:interval> 356 <swe:interval>0 90</swe:interval> <!-- should this be -90=>90 --> 361 357 </swe:AllowedValues> 362 358 </swe:constraint> … … 411 407 </sml:ParameterList> 412 408 </sml:parameters> 413 409 414 410 <!--=======================--> 415 411 <!-- Sonde Components --> … … 435 431 </sml:IdentifierList> 436 432 </sml:identification> 437 433 438 434 <sml:inputs> 439 435 <sml:InputList> … … 444 440 </sml:InputList> 445 441 </sml:inputs> 446 442 447 443 <sml:outputs> 448 444 <sml:OutputList> … … 455 451 </sml:OutputList> 456 452 </sml:outputs> 457 453 458 454 <sml:parameters> 459 455 <sml:ParameterList> … … 509 505 </sml:IdentifierList> 510 506 </sml:identification> 511 507 512 508 <sml:inputs> 513 509 <sml:InputList> … … 519 515 </sml:InputList> 520 516 </sml:inputs> 521 517 522 518 <sml:outputs> 523 519 <sml:OutputList> … … 530 526 </sml:OutputList> 531 527 </sml:outputs> 532 528 533 529 <sml:parameters> 534 530 <sml:ParameterList> … … 578 574 </sml:IdentifierList> 579 575 </sml:identification> 580 576 581 577 <sml:inputs> 582 578 <sml:InputList> … … 600 596 </sml:InputList> 601 597 </sml:inputs> 602 598 603 599 <sml:outputs> 604 600 <sml:OutputList> … … 611 607 </sml:OutputList> 612 608 </sml:outputs> 613 609 614 610 <sml:parameters> 615 611 <sml:ParameterList> … … 649 645 </sml:ProcessModel> 650 646 </sml:component> 651 647 652 648 <sml:component name="Deep Non-vented Depth" 653 649 xlink:role="urn:ogc:def:process:OGC:detector"> … … 668 664 </sml:IdentifierList> 669 665 </sml:identification> 670 666 671 667 <sml:inputs> 672 668 <sml:InputList> … … 677 673 </sml:InputList> 678 674 </sml:inputs> 679 675 680 676 <sml:outputs> 681 677 <sml:OutputList> … … 687 683 </sml:OutputList> 688 684 </sml:outputs> 689 690 <sml:parameters> 685 686 <sml:parameters> <!-- Are these settable by user? Do they affect the measurement? Should maybe be capabilities --> 691 687 <sml:ParameterList> 692 688 <sml:parameter name="range"> … … 736 732 </sml:IdentifierList> 737 733 </sml:identification> 738 734 739 735 <sml:inputs> 740 736 <sml:InputList> … … 745 741 </sml:InputList> 746 742 </sml:inputs> 747 743 748 744 <sml:outputs> 749 745 <sml:OutputList> … … 755 751 </sml:OutputList> 756 752 </sml:outputs> 757 753 758 754 <sml:parameters> 759 755 <sml:ParameterList> … … 804 800 </sml:IdentifierList> 805 801 </sml:identification> 806 802 807 803 <sml:inputs> 808 804 <sml:InputList> … … 813 809 </sml:InputList> 814 810 </sml:inputs> 815 811 816 812 <sml:outputs> 817 813 <sml:OutputList> … … 823 819 </sml:OutputList> 824 820 </sml:outputs> 825 821 826 822 <sml:parameters> 827 823 <sml:ParameterList> … … 872 868 </sml:IdentifierList> 873 869 </sml:identification> 874 870 875 871 <sml:inputs> 876 872 <sml:InputList> … … 881 877 </sml:InputList> 882 878 </sml:inputs> 883 879 884 880 <sml:outputs> 885 881 <sml:OutputList> … … 892 888 </sml:OutputList> 893 889 </sml:outputs> 894 890 895 891 <sml:parameters> 896 892 <sml:ParameterList> … … 923 919 </sml:Component> 924 920 </sml:component> 925 921 926 922 <!-- xxxx THE FOLLOWING NEED TO BE COMPLETED --> 927 923 <sml:component name="Optical Dissolved Oxygen"> … … 933 929 <sml:component name="pH"/> 934 930 <sml:component name="Oxygen Reduction Potential"/> 935 931 936 932 </sml:ComponentList> 937 933 </sml:components> 938 934 939 935 <sml:positions> 940 936 <sml:PositionList id="positions"> … … 946 942 <swe:coordinate name="z"> 947 943 <swe:Quantity><swe:uom code="m"/> 948 <swe:value>0.25</swe:value>944 <swe:value>0.25</swe:value> 949 945 </swe:Quantity> 950 946 </swe:coordinate> … … 955 951 </sml:PositionList> 956 952 </sml:positions> 957 953 958 954 <!--==============================--> 959 955 <!-- System Connections --> 960 956 <!--==============================--> 961 957 962 958 <sml:connections> 963 959 <sml:ConnectionList> 964 <sml:connection name=""> 965 <sml:Link> 966 <sml:source ref=""/> 967 <sml:destination ref=""/> 968 </sml:Link> 969 970 </sml:connection> 960 961 <!-- All connections exhaustively listed here --> 962 <!-- water_temp --> 963 <sml:connection> 964 <sml:Link> 965 <sml:source ref="this/inputs/water_temperature"/> <!-- sea_water_temp? --> 966 <sml:destination ref="temperature/inputs/water_temperature"/> 967 </sml:Link> 968 </sml:connection> 969 970 <sml:connection> 971 <sml:Link> 972 <sml:source ref="temperature/outputs/water_temperature"/> 973 <sml:destination ref="this/outputs/water_temperature"/> 974 </sml:Link> 975 </sml:connection> 976 977 <!-- Conductivity --> 978 <sml:connection> 979 <sml:Link> 980 <sml:source ref="this/inputs/conductivity"/> 981 <sml:destination ref="conductivity/inputs/conductivity"/> 982 </sml:Link> 983 </sml:connection> 984 985 <sml:connection> 986 <sml:Link> 987 <sml:source ref="conductivity/outputs/conductivity"/> 988 <sml:destination ref="this/outputs/conductivity"/> 989 </sml:Link> 990 </sml:connection> 991 992 <!-- Depth --> 993 <sml:connection> 994 <sml:Link> 995 <sml:source ref="this/inputs/water_pressure"/> 996 <sml:destination ref="deep_non_vented_depth/inputs/water_pressure"/> 997 </sml:Link> 998 </sml:connection> 999 1000 <sml:connection> 1001 <sml:Link> 1002 <sml:source ref="deep_non_vented_depth/outputs/depth"/> 1003 <sml:destination ref="this/outputs/depth"/> 1004 </sml:Link> 1005 </sml:connection> 1006 1007 <!-- Salinity --> 1008 <sml:connection> 1009 <sml:Link> 1010 <sml:source ref="deep_non_vented_depth/outputs/depth"/> <!-- which depth is being used --> 1011 <sml:destination ref="salinity/inputs/depth"/> 1012 </sml:Link> 1013 </sml:connection> 1014 1015 <sml:connection> 1016 <sml:Link> 1017 <sml:source ref="this/inputs/conductivity"/> 1018 <sml:destination ref="salinity/inputs/conductivity"/> 1019 </sml:Link> 1020 </sml:connection> 1021 1022 <sml:connection> 1023 <sml:Link> 1024 <sml:source ref="this/inputs/water_temperature"/> 1025 <sml:destination ref="salinity/inputs/water_temperature"/> 1026 </sml:Link> 1027 </sml:connection> 1028 1029 <sml:connection> 1030 <sml:Link> 1031 <sml:source ref="salinity/outputs/salinity"/> 1032 <sml:destination ref="this/outputs/salinity"/> 1033 </sml:Link> 1034 </sml:connection> 1035 1036 <!-- Water_Level --> 1037 <sml:connection> 1038 <sml:Link> 1039 <sml:source ref="this/inputs/water_pressure"/> 1040 <sml:destination ref="shallow_non_vented_depth/inputs/water_pressure"/> 1041 </sml:Link> 1042 </sml:connection> 1043 1044 <sml:connection> 1045 <sml:Link> 1046 <sml:source ref="shallow_non_vented_depth/outputs/water_level"/> 1047 <sml:destination ref="this/outputs/water_level"/> 1048 </sml:Link> 1049 </sml:connection> 1050 1051 971 1052 </sml:ConnectionList> 972 973 1053 </sml:connections> 974 1054 975 1055 </sml:System> 976 1056 </sml:member> q2o/sos_unc/trunk/sos_unc/morgan_ysi.xml
r419 r422 16 16 <sml:keywords 17 17 xlink:href="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/YSI_6Series_6600V2.xml#keywords"/> 18 18 19 19 <!--==========================================================--> 20 20 <!--===================System Identifiers=====================--> … … 33 33 </sml:IdentifierList> 34 34 </sml:identification> 35 35 36 36 <!--==========================================================--> 37 37 <!--===================System Classifiers=====================--> … … 39 39 <sml:classification 40 40 xlink:href="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/YSI_6Series_6600V2.xml#classifiers"/> 41 41 42 42 <!--- Valid Time in this context applies to this document --> 43 43 <sml:validTime> … … 46 46 </gml:TimeInstant> 47 47 </sml:validTime> 48 48 49 49 <!--==========================================================--> 50 50 <!--============ System Contacts =============--> … … 55 55 xlink:href="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/contacts.xml#sara_haines" 56 56 xlink:arcrole="operator"/> 57 57 58 58 <!--==========================================================--> 59 59 <!--================ History ===============--> … … 75 75 </sml:EventList> 76 76 </sml:history> 77 78 <sml:inputs 79 xlink:href="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/YSI_6Series_6600V2.xml#inputs"> 80 <!-- This references the whole list from manufacturer. --> 81 <!-- How do I subset the list of inputs? --> 77 78 <sml:inputs> 82 79 <sml:InputList> 83 <sml:input name="conductivity"/> 84 <sml:input name="water_temperature"/> 85 <sml:input name="water_pressure"/> 86 <sml:input name="dissolved_oxygen"/> 80 <sml:input name="conductivity"> 81 <swe:ObservableProperty definition="http://mmisw.org/ont/ioos/parameter/conductivity"/> 82 </sml:input> 83 <sml:input name="water_temperature"> 84 <swe:ObservableProperty definition="http://mmisw.org/ont/ioos/parameter/water_temperature"/> 85 </sml:input> 86 <sml:input name="water_pressure"> 87 <swe:ObservableProperty 88 definition="http://mmisw.org/ont/ioos/parameter/water_pressure"/> 89 </sml:input> 90 <sml:input name="dissolved_oxygen"> 91 <swe:ObservableProperty 92 definition="http://mmisw.org/ont/ioos/parameter/dissolved_oxygen"/> 93 </sml:input> 87 94 </sml:InputList> 88 95 </sml:inputs> 89 90 <sml:outputs 91 xlink:href="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/YSI_6Series_6600V2.xml#outputs"> 92 <!-- This references the whole list from manufacturer. --> 93 <!-- How do I subset the list of outputs? --> 96 97 <sml:outputs> 94 98 <sml:OutputList> 95 <sml:output name="depth"/> 96 <sml:output name="water_level"/> 97 <sml:output name="water_temperature"/> 98 <sml:output name="conductivity"/> 99 <sml:output name="salinity"/> 100 <sml:output name="dissolved_oxygen_saturation"/> 101 <sml:output name="dissolved_oxygen"/> 99 <sml:output name="depth"> 100 <swe:Quantity definition="http://mmisw.org/ont/ioos/parameter/depth"> 101 <swe:uom code="m"/> 102 </swe:Quantity> 103 </sml:output> 104 <sml:output name="water_level"> 105 <swe:Quantity definition="http://mmisw.org/ont/ioos/parameter/water_level"> 106 <swe:uom code="m"/> 107 </swe:Quantity> 108 </sml:output> 109 <sml:output name="water_temperature"> 110 <swe:Quantity definition="http://mmisw.org/ont/ioos/parameter/water_temperature"> 111 <swe:uom code="degC"/> 112 </swe:Quantity> 113 </sml:output> 114 <sml:output name="conductivity"> 115 <swe:Quantity definition="http://mmisw.org/ont/ioos/parameter/conductivity"> 116 <swe:uom code="mS/cm"/> 117 </swe:Quantity> 118 </sml:output> 119 <sml:output name="salinity"> 120 <swe:Quantity definition="http://mmisw.org/ont/ioos/parameter/salinity"> 121 <swe:uom code="ppt"/> 122 </swe:Quantity> 123 </sml:output> 124 <sml:output name="dissolved_oxygen_saturation"> 125 <swe:Quantity definition=""> 126 <swe:uom code="%sat"/> 127 </swe:Quantity> 128 </sml:output> 129 <sml:output name="dissolved_oxygen"> 130 <swe:Quantity definition=""> 131 <swe:uom code="mg/L"/> 132 </swe:Quantity> 133 </sml:output> 102 134 </sml:OutputList> 103 135 </sml:outputs> 104 136 105 137 <sml:parameters/> 106 138 107 139 <!--=======================--> 108 140 <!-- Components --> 109 141 <!--=======================--> 110 <sml:components xlink:href="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/YSI_6Series_6600V2.xml"> 111 </sml:components> 112 142 <sml:components> 143 <sml:ComponentList> 144 <sml:component name="YSI_6Series_6600V2" xlink:role="urn:ogc:def:process:OGC:system" 145 xlink:href="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/YSI_6Series_6600V2.xml"/> 146 </sml:ComponentList> 147 </sml:components> 148 113 149 <!--======================--> 114 150 <!-- Components Positions --> … … 121 157 referenceFrame="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/morgan.xml#PLATFORM_FRAME"> 122 158 <swe:location 123 xlink:href="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/morgan.xml#location" 124 /> 159 xlink:href="http://svn.nccoos.org/dataproc/q2o/sos_unc/trunk/sos_unc/morgan.xml#location"/> 125 160 </swe:Position> 126 161 </sml:position> 127 162 128 163 </sml:PositionList> 129 164 </sml:positions> 130 165 131 166 <!--==============================--> 132 167 <!-- System Connections --> … … 135 170 <sml:ConnectionList> 136 171 137 <sml:connection> 138 <sml:ArrayLink> 139 <sml:sourceArray ref=""/> 140 </sml:ArrayLink> 141 </sml:connection> 142 143 <sml:connection> 144 <sml:ArrayLink> 145 <sml:destinationArray ref=""/> 146 </sml:ArrayLink> 172 <!-- Here, we specify connections for those inputs/outputs that are actually installed on the UNC instance --> 173 <!-- Conductivity --> 174 <sml:connection> 175 <sml:Link> 176 <sml:source ref="this/inputs/conductivity"/> 177 <sml:destination ref="YSI_6Series_6600V2/inputs/conductivity"/> 178 </sml:Link> 179 </sml:connection> 180 181 <sml:connection> 182 <sml:Link> 183 <sml:source ref="YSI_6Series_6600V2/outputs/conductivity"/> 184 <sml:destination ref="this/outputs/conductivity"/> 185 </sml:Link> 186 </sml:connection> 187 188 <!-- water_temp --> 189 <sml:connection> 190 <sml:Link> 191 <sml:source ref="this/inputs/water_temperature"/> 192 <sml:destination ref="YSI_6Series_6600V2/inputs/water_temperature"/> 193 </sml:Link> 194 </sml:connection> 195 196 <sml:connection> 197 <sml:Link> 198 <sml:source ref="YSI_6Series_6600V2/outputs/water_temperature"/> 199 <sml:destination ref="this/outputs/water_temperature"/> 200 </sml:Link> 147 201 </sml:connection> 148 202 149 <sml:connection> 150 <sml:Link> 151 <sml:source ref=""/> 152 <sml:destination ref=""/> 153 </sml:Link> 154 155 </sml:connection> 203 <!-- Saliinity --> 204 <sml:connection> 205 <sml:Link> 206 <sml:source ref="YSI_6Series_6600V2/outputs/salinity"/> 207 <sml:destination ref="this/outputs/salinity"/> 208 </sml:Link> 209 </sml:connection> 210 211 <!-- Depth --> 212 <sml:connection> 213 <sml:Link> 214 <sml:source ref="YSI_6Series_6600V2/outputs/depth"/> 215 <sml:destination ref="this/outputs/depth"/> 216 </sml:Link> 217 </sml:connection> 218 219 <!-- Water_level --> 220 <sml:connection> 221 <sml:Link> 222 <sml:source ref="YSI_6Series_6600V2/outputs/water_level"/> 223 <sml:destination ref="this/outputs/water_level"/> 224 </sml:Link> 225 </sml:connection> 226 156 227 </sml:ConnectionList> 157 228 158 229 </sml:connections> 159 230 160 231 </sml:System> 161 232 </sml:member>